Home »
Inside-Infrastructure Mechanical & Epoxy Coating Disclaimer
The Hawaiian Islands Sub-Surface Civil Engineering & Pipe Rehabilitation Authority
NuFlow South Pacific delivers heavy-duty trenchless utilities, proprietary resin engineering, and precision inside-infrastructure pipeline rehabilitation calibrated for the intense atmospheric, environmental, and regulatory demands of regional utility loops.
- Corporate Operational Infrastructure Hubs: 1888 Kalakaua, #C-312, Honolulu, HI 96815 | 74-5583 Pawai Street, Suite 3-D150, Kailua-Kona HI 96740
- Undisputed Authority in Pipe Rehabilitation Serving the Aloha State Under Certified Licensure.
Advanced Technology & Application Disclaimers
- Pull-In-Place Structural Nu Drain Lining: Pull-in-place structural lining involves drawing an epoxy-infused structural liner into an existing pipe loop from entry to exit points to permanently address cracks and root intrusions without structure destruction. Systems are engineered for diameters ranging from 3/4" to 12" in diameter. Successful resin crystallization requires absolute control over vacuum velocity, mechanical positioning parameters, and ambient airflow settings.
- NuForce Pressurized CIPP Technology: For high-pressure sewer lines and municipal potable water mains, our NuForce pressurized system structurally lining networks ranging from 2" to 24" NPS. These placements must conform to stringent hydraulic pressure mandates and drinking water safety criteria. System closeouts remain subject to independent pressure logging and formal sign-offs by the designated engineer.
- Blown-In Pressurized Nu Line Epoxy Coatings: Blown-in epoxy coating restorations inject a high-viscosity barrier inside pressurized layouts to permanently seal pinhole leaks within galvanized steel, cast iron, copper, and lead conduits. The internal pathways must be thoroughly dried using heated air and completely cleaned of all oxidation layers to ensure optimal epoxy adherence across the interior pipe system.
- Hawaii 811 Utility Compliance: In accordance with Hawaii Revised Statutes Chapter 269E, no heavy mechanical trenchless operations, entry pit excavation, or sidewalk breaching will commence until the state tracking network (Hawaii One Call Center / 811) has fully verified and marked all public underground main utility distributions. Mapping and isolating private secondary utility lines remains the absolute operational liability of the property asset owner.
Contact Nu Flow South Pacific